Disconnect power to the unit.
- Remove the jumper from the “Tamper” (P2) header with a pair of needle-nose pliers.
- Place this jumper on the P65 header on the two pins closest to the “Tamper” (P2) header.
- Apply power to the unit.
- The “System Activity” LED will become solid amber.
- With the “System Activity” LED amber, remove the jumper from the P65 header.
- Place this jumper back on the P65 header of the two pins closest to the “Tamper” (P2) header after the LED has gone from amber to red OR off.
- NOTE 1: Timing of the reinstallation of the jumper is critical otherwise you will need to follow the entire procedure again.
- The “System Activity” LED will then again become solid amber.
- Remove the jumper and reinstall it on the “Tamper” (P2) header.
- The “System Activity” LED will flash briefly, go out, and then within 60 seconds return to the normal green state.
- Connect to the unit via the JumpStart application, configured IP Address, or Alias IP Address.
- The web browser will prompt for a username and password.
- If this is a Solo 1.2 unit, then login with username: admin and the password will be the 8-digit alphanumeric value you obtained from HID Global Technical Support. If using PRE – Solo 1.2 login with username: user and the password will be the 8-digit alphanumeric value you obtained from HID Global Technical Support. If this is an EDGE host unit, the password will be blank on the first login. You must set a new password before logging off.
- It is recommend you immediately go and modify the password(s) using the “Password” option within the Installer Settings Tab.
RE-CONFIGURE UNIT
- Go into unit via HID discovery
- change host IP address to the PC ip address of Access Metrics
- change here I am time to 20 seconds